The use of Electrical Resistivity Tomography and Induced Polarization to investigate seepage conditions in a Hydroelectric Dam (A case study of the East Dike of the Kpong Hydro Dam)

dc.contributor.authorDery, Clement Yizaa
dc.contributor.author
dc.date.accessioned2021-07-09T13:50:20Z
dc.date.accessioned2023-04-19T04:36:05Z
dc.date.available2021-07-09T13:50:20Z
dc.date.available2023-04-19T04:36:05Z
dc.date.issuedNovember,2019
dc.descriptionA thesis submitted to the Department of Geological Engineering (Faculty of Civil and Geo-Engineering) College of Engineering in partial fulfilment of the requirements for the degree of Master of Science (Geophysical Engineering)en_US
dc.description.abstractEarth dams are designed to permit the flow of seepage water from their reservoir through designed filter zones and relief wells. However, the flow of seepage water through other preferential flow paths either than the designed filter zones and relief wells can be detrimental to the overall stability of the dam. Conventional inspection methods such as surveillance and installation of instruments including inclinometers and settlement monuments are commonly used to detect anomalous conditions which can lead to failure on earth dams. These methods however usually detect these causes of failure after it has worsened. Geophysical techniques are non-invasive, cover a large area of the survey and are able to detect relatively small changes in physical contrast within an earth dam when used repeatedly. The ERT and IP methods were used to delineate possible seepage zones and pathways of unplanned seepage conditions that have occurred on the downstream side of the east dike of the Kpong Hydroelectric dam in Akuse, Ghana. Analysis of ERT results from the four traverse lines established along the east dike show significant anomalous conditions suggesting the existence of an unplanned seepage pathway within the lower sand and gravel overburden foundation of the dike. Very low resistivity zones (<25 Ωm) at different distances along the embankment was detected to be potential seepage zones. Also, the potential unplanned seepage pathway was delineated at an average elevation of 7m NDL and from 42m distance from the start of the traverse lines to 112m towards the end of the traverse lines. The IP results could not effectively detect and delineate the potential unplanned seepage zones and pathways.en_US
dc.description.sponsorshipKNUSTen_US
dc.identifier.urihttps://ir.knust.edu.gh/handle/123456789/14317
dc.language.isoen_USen_US
dc.subjectElectrical Resistivity Tomographyen_US
dc.subjectInduced Polarizationen_US
dc.subjectInvestigatiomen_US
dc.subjectSeepage conditionsen_US
dc.subjectHydroelectric Damen_US
dc.subjectEast Dikeen_US
dc.subjectKpong Hydro Damen_US
dc.titleThe use of Electrical Resistivity Tomography and Induced Polarization to investigate seepage conditions in a Hydroelectric Dam (A case study of the East Dike of the Kpong Hydro Dam)en_US
dc.typeThesisen_US
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Clement Yizaa Dery_ Msc.pdf
Size:
3.76 MB
Format:
Adobe Portable Document Format
Description:
Full Thesis
License bundle
Now showing 1 - 2 of 2
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.73 KB
Format:
Item-specific license agreed to upon submission
Description:
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed to upon submission
Description: