Assessment of the quality of water used for domestic activities in Achimota School

dc.contributor.authorAsiedu, Michael
dc.date.accessioned2016-04-01T13:13:14Z
dc.date.accessioned2023-04-19T20:36:41Z
dc.date.available2016-04-01T13:13:14Z
dc.date.available2023-04-19T20:36:41Z
dc.date.issuedAUGUST, 2015
dc.descriptionA thesis submitted to the Department of Theoretical and Applied Biology, Kwame Nkrumah University of Science and Technology in partial fulfillment of the requirements Master of Science degree in Environmental Science.en_US
dc.description.abstractThe study was conducted to assess the bacteriological and physico-chemical quality of potable water provided by Ghana Water Company Limited and borehole (underground) water used as domestic water supply in Achimota School. People in this area use the water for cooking, bathing, washing clothes and some even drink it. Thirteen (13) samples of tap water were collected from thirteen different areas while four (4) samples from boreholes from different locations within the Achimota School in the Accra Metro West District in the Greater Accra Region of Ghana were analysed. It was conducted between August 2010 and December 2010. Physico-chemical parameters such as calcium, magnesium, sodium, potassium, bicarbonate, carbonate, sulphate, chloride, total iron, manganese, fluoride, pH, total alkalinity, conductivity, total dissolved solids, nitrate, nitrite, turbidity and phosphate were determined using conventional methods. Indicators for bacteria contamination due to presence of total coliforms and faecal coliforms were also carried out. All the pH recorded fell within WHO (2006) limits except tap water from Hospital Area that had a pH of 5.72. The remaining physio-chemical parameters for both waters fell within the desirable limits of WHO (2006) standards for drinking water. Bacteriologically, total coliforms ranging from 15 - 651 CFU 100 ml-1, were present in all the samples taken. Out of the tap water samples taken, about 50 % (McCarthy House, Anumle, Slessor House, Hospital Area and Achimota Preparatory School Area) and 25 % of borehole (thus Clark House) had faecal coliforms in them. But none of the waters sampled had E. coli. Therefore, both tap and borehole waters within the study area need some suitable treatments to make them safe bacteriologically for drinking. Regular monitoring and effective disinfestations are also needed to reduce the bacteria contamination.en_US
dc.description.sponsorshipKNUSTen_US
dc.identifier.urihttps://ir.knust.edu.gh/handle/123456789/8438
dc.language.isoenen_US
dc.titleAssessment of the quality of water used for domestic activities in Achimota Schoolen_US
dc.typeThesisen_US
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
MICHAEL ASIEDU_M.Phil_2015.pdf
Size:
1.14 MB
Format:
Adobe Portable Document Format
Description:
Full Thesis.
License bundle
Now showing 1 - 2 of 2
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.73 KB
Format:
Item-specific license agreed to upon submission
Description:
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed to upon submission
Description: